Описание оборудования | |
---|---|
LCD batch controller with 6 optocoupler outputs and 90 ... 260 VAC supply voltage | |
General specifications | |
Pre-selection | 6-fold |
Data storage | > 10 years, EEPROM |
Programming | keypad-driven menu |
Functional safety related parameters | |
MTTFd | 410 a |
Mission Time (TM) | 10 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
Type | 2-line, 2x6-digit LC display with leading sign Multicolor, backlit |
Display value | digit height 9 mm |
Pre-selection | digit height 7 mm |
Key interlock | via "high" potential at "LOCK" input |
Decimal point | 0 to max 5 fractional digits |
Scale factor | 0.0001 ... 99.9999 |
Reset | manually or external |
Electrical specifications | |
Fusing | 90…260VAC: T 0.1A |
Operating voltage | 90 ... 260 V AC |
Power consumption | max. 8 VA |
Input | |
Connection | Counter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI |
Signal voltage | |
Counting frequency | max. 50 kHz |
Minimum pulse duration | Control/reset inputs: 10 ms / 1 ms |
Impedance | 5 kOhm |
Count modes | |
Output | |
Sensor supply | 20.4 ... 27.6 V DC, max. 80 mA |
Response time | Add/Sub/autorepeat < 6 ms A/B; (A-B)/A: < 23 ms |
Optocoupler | output 1 to 6, NPN-Opto coupler output 3 to 6 with common emitter Schaltleistung 30 V DC / 10 mA |
Signal voltage | UCESAT with IC= 10mA: max. 2 V UCESAT with IC= 5mA: max. 0.4 V |
Compliance with standards and directives | |
Directive conformity | |
Standard conformity | |
Ambient conditions | |
Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) |
Storage temperature | -25 ... 75 °C (-13 ... 167 °F) |
Relative humidity | ? 93 % at 40 °C (noncondensing) |
Altitude | 0 ... 2000 m |
Pollution degree | 2 |
Mechanical specifications | |
Degree of protection | IP65 (front) |
Mass | approx. 151 g |
Dimensions | 48mmx48mmx109.8mm |